Chapter 4: Programming Commands54
Revision C 12/09
A798-PG00001C
Select or cancel double-strike
ASCII ESC G n
Hexadecimal 1B 47 n
Decimal 27 71 n
Value of n: 0 = O
1 = On
(When 0 and 1 are the least signicant bit, LSB)
Default: 0 (O)
Turns double-strike mode on or off. Identical to emphasized mode. The printer is reset to the standard print mode after a
clear printer (0x10) command is received.
Exceptions
Only the lowest bit of n is effective. The settings do not apply in page mode. However they can be set or cleared in page
mode.
Double-strike printing cannot be used with bit-images or downloaded bit-images.
Related information
This command and the select print mode(s) command (1B 21) function identically. They should have the same setting
when used together.
In A793 emulation, this command is unrecognized and the parameter byte is put into the print buffer.
Select or cancel italic print
ASCII ESC I n
Hexadecimal 1B 49 n
Decimal 27 73 n
Value of n: 0 = O
1 = On
(When 0 and 1 are the least signicant bit, LSB)
Default: 0 (O)
Turns italic print mode on or off. The printer is reset to the standard print mode after a clear printer (0x10) command is
received.
Exceptions
Only the lowest bit of n is valid.
Related information
This command is recognized in A798 native mode and A794 emulation.
In A793 and LEGACY emulations, the parameter byte is put into the buffer.